diff --git a/Documentation/devicetree/bindings/thermal/thermal-zones.yaml b/Documentation/devicetree/bindings/thermal/thermal-zones.yaml index 0de0a9757ccc..07d9f576ffe7 100644 --- a/Documentation/devicetree/bindings/thermal/thermal-zones.yaml +++ b/Documentation/devicetree/bindings/thermal/thermal-zones.yaml @@ -129,63 +129,60 @@ patternProperties: which the thermal framework needs to take action. The actions to be taken are defined in another node called cooling-maps. - patternProperties: - "^[a-zA-Z][a-zA-Z0-9\\-_]{0,63}$": - type: object + additionalProperties: + type: object + additionalProperties: false - properties: - temperature: - $ref: /schemas/types.yaml#/definitions/int32 - minimum: -273000 - maximum: 200000 - description: - An integer expressing the trip temperature in millicelsius. + properties: + temperature: + $ref: /schemas/types.yaml#/definitions/int32 + minimum: -273000 + maximum: 200000 + description: + An integer expressing the trip temperature in millicelsius. - hysteresis: - $ref: /schemas/types.yaml#/definitions/uint32 - description: - An unsigned integer expressing the hysteresis delta with - respect to the trip temperature property above, also in - millicelsius. Any cooling action initiated by the framework is - maintained until the temperature falls below - (trip temperature - hysteresis). This potentially prevents a - situation where the trip gets constantly triggered soon after - cooling action is removed. + hysteresis: + $ref: /schemas/types.yaml#/definitions/uint32 + description: + An unsigned integer expressing the hysteresis delta with + respect to the trip temperature property above, also in + millicelsius. Any cooling action initiated by the framework is + maintained until the temperature falls below + (trip temperature - hysteresis). This potentially prevents a + situation where the trip gets constantly triggered soon after + cooling action is removed. - type: - $ref: /schemas/types.yaml#/definitions/string - enum: - - active # enable active cooling e.g. fans - - passive # enable passive cooling e.g. throttling cpu - - hot # send notification to driver - - critical # send notification to driver, trigger shutdown - description: | - There are four valid trip types: active, passive, hot, - critical. + type: + $ref: /schemas/types.yaml#/definitions/string + enum: + - active # enable active cooling e.g. fans + - passive # enable passive cooling e.g. throttling cpu + - hot # send notification to driver + - critical # send notification to driver, trigger shutdown + description: | + There are four valid trip types: active, passive, hot, + critical. - The critical trip type is used to set the maximum - temperature threshold above which the HW becomes - unstable and underlying firmware might even trigger a - reboot. Hitting the critical threshold triggers a system - shutdown. + The critical trip type is used to set the maximum + temperature threshold above which the HW becomes + unstable and underlying firmware might even trigger a + reboot. Hitting the critical threshold triggers a system + shutdown. - The hot trip type can be used to send a notification to - the thermal driver (if a .notify callback is registered). - The action to be taken is left to the driver. + The hot trip type can be used to send a notification to + the thermal driver (if a .notify callback is registered). + The action to be taken is left to the driver. - The passive trip type can be used to slow down HW e.g. run - the CPU, GPU, bus at a lower frequency. + The passive trip type can be used to slow down HW e.g. run + the CPU, GPU, bus at a lower frequency. - The active trip type can be used to control other HW to - help in cooling e.g. fans can be sped up or slowed down + The active trip type can be used to control other HW to + help in cooling e.g. fans can be sped up or slowed down - required: - - temperature - - hysteresis - - type - additionalProperties: false - - additionalProperties: false + required: + - temperature + - hysteresis + - type cooling-maps: type: object