+/-1200uT is a MAGN sensor full measurement range. Magnetometer scale
is the magnetic sensitivity parameter. It is referenced as 0.1uT
according to datasheet and magnetometer channel unit is Gauss in
sysfs-bus-iio documentation. Gauss and uTesla unit conversion
relationship as follows: 0.1uT = 0.001Gs.
Set magnetometer scale and available magnetometer scale as fixed 0.001Gs.
Fixes: 84e5ddd5c4 ("iio: imu: Add support for the FXOS8700 IMU")
Signed-off-by: Carlos Song <carlos.song@nxp.com>
Link: https://lore.kernel.org/r/20230118074227.1665098-5-carlos.song@nxp.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
When device is in active mode, it fails to set an ACCEL full-scale
range(2g/4g/8g) in FXOS8700_XYZ_DATA_CFG. This is not align with the
datasheet, but it is a fxos8700 chip behavior.
Keep the device in standby mode before setting ACCEL full-scale range
into FXOS8700_XYZ_DATA_CFG in chip initialization phase and setting
scale phase.
Fixes: 84e5ddd5c4 ("iio: imu: Add support for the FXOS8700 IMU")
Signed-off-by: Carlos Song <carlos.song@nxp.com>
Link: https://lore.kernel.org/r/20221208071911.2405922-6-carlos.song@nxp.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
ACCEL output data registers contain the X-axis, Y-axis, and Z-axis
14-bit left-justified sample data and MAGN output data registers
contain the X-axis, Y-axis, and Z-axis 16-bit sample data. The ACCEL
raw register output data should be divided by 4 before sent to
userspace.
Apply a 2 bits signed right shift to the raw data from ACCEL output
data register but keep that from MAGN sensor as the origin.
Fixes: 84e5ddd5c4 ("iio: imu: Add support for the FXOS8700 IMU")
Signed-off-by: Carlos Song <carlos.song@nxp.com>
Link: https://lore.kernel.org/r/20221208071911.2405922-5-carlos.song@nxp.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The length of ACCEL and MAGN 3-axis channels output data is 6 byte
individually. However block only read 3 bytes data into buffer from
ACCEL or MAGN output data registers every time. It causes an incomplete
ACCEL and MAGN channels readback.
Set correct value count for regmap_bulk_read to get 6 bytes ACCEL and
MAGN channels readback.
Fixes: 84e5ddd5c4 ("iio: imu: Add support for the FXOS8700 IMU")
Signed-off-by: Carlos Song <carlos.song@nxp.com>
Link: https://lore.kernel.org/r/20221208071911.2405922-4-carlos.song@nxp.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch applies the semantic patch:
@@
expression I, P, SP;
@@
I = devm_iio_device_alloc(P, SP);
...
- I->dev.parent = P;
It updates 302 files and does 307 deletions.
This semantic patch also removes some comments like
'/* Establish that the iio_dev is a child of the i2c device */'
But this is is only done in case where the block is left empty.
The patch does not seem to cover all cases. It looks like in some cases a
different variable is used in some cases to assign the parent, but it
points to the same reference.
In other cases, the block covered by ... may be just too big to be covered
by the semantic patch.
However, this looks pretty good as well, as it does cover a big bulk of the
drivers that should remove the parent assignment.
Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
FXOS8700CQ is a small, low-power, 3-axis linear accelerometer and 3-axis
magnetometer combined into a single package. The device features a
selectable I2C or point-to-point SPI serial interface with 14-bit
accelerometer and 16-bit magnetometer ADC resolution along with
smart-embedded functions.
FXOS8700CQ has dynamically selectable accelerationfull-scale ranges of
±2 g/±4 g/±8 g and a fixed magnetic measurement range of ±1200 μT.
Output data rates (ODR) from 1.563 Hz to 800 Hz are selectable by the user
for each sensor. Interleaved magnetic and acceleration data is available
at ODR rates of up to 400 Hz. FXOS8700CQ is available in a plastic QFN
package and it is guaranteed to operate over the extended temperature
range of –40 °C to +85 °C.
TODO: Trigger and IRQ configuration support
Datasheet:
http://cache.freescale.com/files/sensors/doc/data_sheet/FXOS8700CQ.pdf
Signed-off-by: Robert Jones <rjones@gateworks.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>