The PTP clock for the Tegra234 MGBE device is incorrectly named
'ptp-ref' and should be 'ptp_ref'. This is causing the following
warning to be observed on Tegra234 platforms that use this device:
ERR KERN tegra-mgbe 6800000.ethernet eth0: Invalid PTP clock rate
WARNING KERN tegra-mgbe 6800000.ethernet eth0: PTP init failed
Although this constitutes an ABI breakage in the binding for this
device, PTP support has clearly never worked and so fix this now
so we can correct the device-tree for this device. Note that the
MGBE driver still supports the legacy 'ptp-ref' clock name and so
older/existing device-trees will still work, but given that this
is not the correct name, there is no point to advertise this in the
binding.
Fixes: 189c2e5c76 ("dt-bindings: net: Add Tegra234 MGBE")
Signed-off-by: Jon Hunter <jonathanh@nvidia.com>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@oss.qualcomm.com>
Link: https://patch.msgid.link/20260401102941.17466-3-jonathanh@nvidia.com
Signed-off-by: Jakub Kicinski <kuba@kernel.org>