With OD settings applied, the clock table will be updated accordingly.
We need to retrieve the new clock tables then.
Signed-off-by: Evan Quan <evan.quan@amd.com>
Acked-by: Alex Deucher <alexander.deucher@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
With the latest SMC fw, we are able to get the voltage value for
specific frequency point. So, we update the OD relates to take
absolute voltage instead of offset.
Signed-off-by: Evan Quan <evan.quan@amd.com>
Acked-by: Alex Deucher <alexander.deucher@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
SOC voltage is not able to switch and forced to low 0.8V when running HEVC.
Thus the test failed.
Signed-off-by: Evan Quan <evan.quan@amd.com>
Reviewed-by: Rex Zhu <rezhu@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
hwmgr is the interface for the driver to setup state
structures which are used by the smu for managing the
power state.
v2: squash in fixes:
- update set_watermarks_for_clocks_ranges to use common code
- drop unsupported apis
- correct MAX_REGULAR_DPM_NUMBER value
- multimonitor fixes
- add check for vbios pptable version
- revise dpm table setup
- init fclk dpm state
- Remove unused definition in vega20_hwmgr
- support power limit setup
- enable vega20 to honour DAL clock limits
- comment out dump_table debugging
v3: switch to SOC15 register access macros
Signed-off-by: Evan Quan <evan.quan@amd.com>
Reviewed-by: Huang Rui <ray.huang@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>