Adjust xcc_id logic to only use physical xcc_id when program
register, (use logic xcc_id by default), to fit for compute
partition.
Signed-off-by: Likun Gao <Likun.Gao@amd.com>
Reviewed-by: Lijo Lazar <lijo.lazar@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
Enable retry faults in both GCVM/MMVM Context1 Control
and L2_PROTECTION_FAULT_CNTL2 registers for GFX 12.1.
Signed-off-by: Mukul Joshi <mukul.joshi@amd.com>
Reviewed-by: Philip Yang <Philip.Yang@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
On GFX 12.1, PDE.C is ignored if (PDE|PTE)_REQUEST_PHYSICAL
is not setup in the GCVM control register. Always set this
field to enable PDE.C usage.
Signed-off-by: Mukul Joshi <mukul.joshi@amd.com>
Reviewed-by: Alex Sierra <alex.sierra@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>