Document the stm32 debug bus. The debug bus is responsible for checking the debug sub-system accessibility before probing any related drivers. Signed-off-by: Gatien Chevallier <gatien.chevallier@foss.st.com> Reviewed-by: Rob Herring (Arm) <robh@kernel.org> Link: https://lore.kernel.org/r/20260226-debug_bus-v6-3-5d794697798d@foss.st.com Signed-off-by: Alexandre Torgue <alexandre.torgue@foss.st.com>
77 lines
1.6 KiB
YAML
77 lines
1.6 KiB
YAML
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
|
|
%YAML 1.2
|
|
---
|
|
$id: http://devicetree.org/schemas/bus/st,stm32mp131-dbg-bus.yaml#
|
|
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
|
|
|
title: STM32 Coresight bus
|
|
|
|
maintainers:
|
|
- Gatien Chevallier <gatien.chevallier@foss.st.com>
|
|
|
|
description:
|
|
The STM32 debug bus is in charge of checking the debug configuration
|
|
of the platform before probing the peripheral drivers that rely on the debug
|
|
domain.
|
|
|
|
properties:
|
|
compatible:
|
|
items:
|
|
- enum:
|
|
- st,stm32mp131-dbg-bus
|
|
- st,stm32mp151-dbg-bus
|
|
|
|
"#address-cells":
|
|
const: 1
|
|
|
|
"#size-cells":
|
|
const: 1
|
|
|
|
ranges:
|
|
minItems: 1
|
|
maxItems: 2
|
|
|
|
"#access-controller-cells":
|
|
const: 1
|
|
description:
|
|
Contains the debug profile necessary to access the peripheral.
|
|
|
|
patternProperties:
|
|
"@[0-9a-f]+$":
|
|
description: Debug related peripherals
|
|
type: object
|
|
|
|
additionalProperties: true
|
|
|
|
required:
|
|
- access-controllers
|
|
|
|
required:
|
|
- "#access-controller-cells"
|
|
- "#address-cells"
|
|
- "#size-cells"
|
|
- compatible
|
|
- ranges
|
|
|
|
additionalProperties: false
|
|
|
|
examples:
|
|
- |
|
|
#include <dt-bindings/clock/stm32mp1-clks.h>
|
|
|
|
dbg_bus: bus@50080000 {
|
|
compatible = "st,stm32mp131-dbg-bus";
|
|
#address-cells = <1>;
|
|
#size-cells = <1>;
|
|
#access-controller-cells = <1>;
|
|
ranges = <0x50080000 0x50080000 0x3f80000>;
|
|
|
|
cti@50094000 {
|
|
compatible = "arm,coresight-cti", "arm,primecell";
|
|
reg = <0x50094000 0x1000>;
|
|
clocks = <&rcc CK_DBG>;
|
|
clock-names = "apb_pclk";
|
|
access-controllers = <&dbg_bus 0>;
|
|
};
|
|
};
|