Files
linux/Documentation/devicetree/bindings/arm/amlogic/amlogic,meson-mx-secbus2.yaml
Martin Blumenstingl 68f3a096d0 dt-bindings: Amlogic: add the documentation for the SECBUS2 registers
The Meson8/Meson8b/Meson8m2 SoCs have a register bank called SECBUS2 which
contains registers for various IP blocks such as pin-controller bits for
the BSD_EN and TEST_N GPIOs as well as some AO ARC core control bits.
The registers can be accessed directly when not running in "secure mode".
When "secure mode" is enabled then these registers have to be accessed
through secure monitor calls.

So far these SoCs are always known to boot in "non-secure mode".
Add a binding documentation using syscon (as these registers are shared
across different IPs) for the SECBUS2 registers.

Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Kevin Hilman <khilman@baylibre.com>
Link: https://lore.kernel.org/r/20210102205904.2691120-3-martin.blumenstingl@googlemail.com
2021-02-03 10:22:10 -08:00

43 lines
1.1 KiB
YAML

# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
%YAML 1.2
---
$id: "http://devicetree.org/schemas/arm/amlogic/amlogic,meson-mx-secbus2.yaml#"
$schema: "http://devicetree.org/meta-schemas/core.yaml#"
title: Amlogic Meson8/Meson8b/Meson8m2 SECBUS2 register interface
maintainers:
- Martin Blumenstingl <martin.blumenstingl@googlemail.com>
description: |
The Meson8/Meson8b/Meson8m2 SoCs have a register bank called SECBUS2 which
contains registers for various IP blocks such as pin-controller bits for
the BSD_EN and TEST_N GPIOs as well as some AO ARC core control bits.
The registers can be accessed directly when not running in "secure mode".
When "secure mode" is enabled then these registers have to be accessed
through secure monitor calls.
properties:
compatible:
items:
- enum:
- amlogic,meson8-secbus2
- amlogic,meson8b-secbus2
- const: syscon
reg:
maxItems: 1
required:
- compatible
- reg
additionalProperties: false
examples:
- |
secbus2: system-controller@4000 {
compatible = "amlogic,meson8-secbus2", "syscon";
reg = <0x4000 0x2000>;
};